Ijraset Journal For Research in Applied Science and Engineering Technology
Authors: Mohammadzunoor Kazi, Sandip P. Chandresha
DOI Link: https://doi.org/10.22214/ijraset.2022.43690
Certificate: View Certificate
Now a day Expanded Polystyrene (EPS) Core Reinforced Concrete Sandwich Panels (RCSP) is become more popular building material, Due to it\'s low Weight, low Thermal Conductivity and low construction time. Also it provide more work ability for the mass production of building. EPS Core (80mm to 120mm) RCSP Panel consist of EPS Core Between two layers of Reinforce concrete, 2mm to 3mm diameter welded coated steel wire mesh use as a Reinforce in concrete. Two Welded wire mesh is connected buy shear connecter of 2mm to 4mm diameter. Up to four story Expanded Polystyrene (EPS) Core Reinforced Concrete Sandwich Panels (RCSP) is using as load bearing wall. And construct structure without beam and column. In this study focus is on comparing G+3 Building using Expanded Polystyrene (EPS) Core Reinforced Concrete Sandwich Panels (RCSP) Located at North Indian city of Sonepat. With Reinforced cement concrete framed structure consist Brick masonry as infill material. In this study building is considered for analysis which is located in zone 5 earth quake region. Static analysis is done using SAP2000 software, soil conditions are to be soft and importance factor is to be taken as 1.2. Various parameters studied like lateral displacement of building, storey drift, base shear, and moment’s and shear force diagrams for a particular beam for both case. Results are represented in graphical as well as in tabular form. The structural members are modelled with the SAP2000 software package. Dead load and live load is considered as per code IS 875:1987 part 1 &2.
I. INTRODUCTION
Expanded Polystyrene (EPS) is use for insulation purpose in industrial and commercial use. In market Expanded Polystyrene (EPS) is popular with name of thermocol. EPS is made from styrene. For construction purpose required size of panel are cut from the block of EPS. Coated steel wire mesh are attached to both sides through shear connecter. After panel are transport to working site that are installing according to plan of building. shotcreting concrete or mortar according to strength required. After shotcreting EPS Panel known as Expanded Polystyrene (EPS) Core Reinforced Concrete Sandwich Panels (RCSP).
RCSP are connected to plinth beam through rebar according to structural engineering requirement. Size and Depth of foundation are decide as per the soil condition and load of structure.
In presents study competition are doing between EPS core RCSP structure and RCC Brick infill structure. In study there is taking same section and size of plinth beam, Also same location of foundation. For both model dead load and load are applying according to IS 875:1987 part 1 &2.
For analysis purpose according to code IS 1893:2016. Brick infill consider as equivalent diagonal strut In witch diagonal strut resist compressive force only & strut are connected with frame through Hinge joint. Thickness of diagonal strut is equal to brick wall’s thickness and Width is decide as per IS code.
Width of equivalent diagonal strut is depend on moment of inertia of adjoin column, length of diagonal strut, Elasticity of Masonry infill and Angle between horizontal and column. In this study for every wall evaluate the width of diagonal strut.
For analysis purpose to carry out Non-Linear Time history Analysis for 3 different time history. And after various parameter study like story displacement, Bending moment & Shear force in Beam and Base Shear. In This study Time History of Three station Gopeshwar, Joshimath and Ukimath taken for 1999 Chamoli earthquake.
II. LITERATURE REVIEW
Adil Ahmad , Yogendra Singh[1] studied detailed seismic safety evaluation of a proposed 4 storey (G+3) Expanded Polystyrene (EPS) core sandwich wall panel building has been performed using pier analysis and finite element method in sap2000.And In this case study model of an EPS core panel based G+3 building constructed in the North Indian city of Sonepat has been developed in SAP 2000. and manual calculate For pier analysis. Modal’s walls and floor slabs are modelled as shell elements, and neglect EPS core and the steel wire mesh have been neglected in the linear analysis. Dead load and live loads apply according to IS: 875 (Part 3)-1987 and earthquake forces apply according to IS 1893 (Part 1):2002. After analysis of fem an manual calculation the stress plots show that the stresses are within the permissible limits of RCC walls (IS 456:2000).
Adil Ahmad , Yogendra Singh[2] Studied practically experimentally studied are doing on 21 specimens are constructed using factory made corrugated EPS panels and wire mesh.The specimens are constructed using different construction (pouring and spraying of concrete) methods, with varying combinations of wythe thicknesses, boundary conditions (presence and detailing of RC beams along the supported edges), and alignment of corrugations in the EPS core. Specimens are tested under four-point bending, with simply supported condition, in displacement control mode. After analysis they conclude that The behavior of NEB specimens (without any edge beam) is distinctly different from REB and MEB specimens. NEB specimens have lower moment of resistance and undergo large deformation. The cracking pattern of MEB specimens is different from REB specimens and these have higher moment capacity but less ductility. The poured concrete specimens crack at higher load in comparison to sprayed concrete specimens.
Ari Wibowo , Indradi Wijatmiko, and Christin R. Nainggolan[3] Are doing practical experiment on specimens witch designed as structural walls composing low-rise building which were commonly found in house or school precast buildings. They are taken 2 specimens RCW4 (EPS panel thickness of 40 mm) and RCW8 (EPS panel thickness of 80 mm). And on that specimen investigate the lateral load-drift behaviors and collapse mechanism.
After analysis they conclude that. Specimen RCW4 with a thinner EPS panel developed more classic flexural behavior with drift capacity maxed at about 1.3%, whilst specimen RCW8 only managed to reached 1.0% with dominant yield penetration behavior due to thinner concrete cover of sloop foundation. However, the tests were stopped at 20% drop of peak load instead of further failure at axial load collapse. hence the results can still be considered satisfactory for low-to-moderate seismic regions but might not be sufficient for high seismic regions.
Fabrizio Gara , Laura Ragni, Davide Roia, Luigino Dezi[4] Investigation carried out on a construction system based on in-situ sandwich panels with non-shear connectors. They doing Compression tests with axial and eccentric loads on full scale panel specimens with different slenderness ratios. and also diagonal compression tests were performed on square specimens in different configurations. They conclude that High ultimate loads decreasing for increasing values of the slenderness ratios for axial and eccentric compression test. And in diagonal compression tests, simple wall panels, prestressed wall panels and panels with transversal stiffening walls were tested. In all these cases high cracking loads were observed. The panels also showed a high capacity for stress redistribution due to metallic mesh inside the concrete layers.
M Fabrizio Gara, Laura Ragni, Davide Roia, Luigino Dez[5] Are evaluate property of floor EPS Sandwich panel through experimat.For testing they built Six panels for flexural tests and two wall–floor nodes Test. In wall-floor panel 600mm long and 160 mm wide floor is connected perpendicular wall panel. Which was 2700mm long and 150 mm wide. They conclude that the experimental results and the numerical simulations of the flexural tests under increasing loads allowed to identify a tri-linear behavior with a very small uncracked phase.
III. RESEARCH METHODOLOGY
For Expanded Polystyrene (EPS) Core Reinforced Concrete Sandwich Panels (RCSP) based G+3 building is located in North Indian city sonepat. For same Architectural drawing both Expanded Polystyrene (EPS) Core Reinforced Concrete Sandwich Panels (RCSP) based building ‘s Model No1 and Brick infill Reinforced cement concrete frame building’s Model No 2 developed in SAP2000.
Dimension of building are 12m width in X-Direction,14.36m long in Y-direction And 13.05 m high, Height of every floor is consider 3m. In both case use same size and length of plinth beam. In analysis consider Dead Load and Live Load as per IS: 875 (Part 1 &2)-1987, For analysis considered Seismic Zone -V and soft soil. Response reduction factor is taken 3. Damping of structure is taken as 5 percent and Important factor is taken as 1.2. For Non- Linear Time History Analysis.
For both Model Grade of concrete taken as M-25 and for reinforcing steel, Fe415 grade of steel is used EPS Core panel consist of 80 mm EPS core placed between two welded wire mesh witch is connected by shear connector(3 diameter wire). Welded wire mese is made of 3mm diameter galvanised steel wire, In wire mesh provide 80mm spacing in horizontal direction and 75mm spacing in vertical direction. M-25 grade micro concrte0 is shotcreting 35 mm in both side of wall and 50 mm and 35 mm in top and bottom layer in slab. Expanded Polystyrene (EPS) Core Reinforced Concrete Sandwich Panels are placed on the plinth beam and connected with the extra steel bar. For analysis purpose define. In Brick infill Reinforced cement concrete frame building brick masonry used as a infill material for outer and partition wall. RC Frame is design as per IS code. For analysis purpose considering as equivalent diagonal compression strut as per IS 1893:2016. In witch as equivalent diagonal compression strut resist compressive force only & strut are connected with frame through Hinge joint. Thickness of diagonal strut is equal to brick wall’s thickness and Width is decide as
Em=550fm
Em= Elasticity of Masonry infill.
Fm=.433fb.64fmo.36
Fb= compressive strength of brick.
fmo= compressive strength of mortar.
Ws =.175αh-.4Lds.
Lds= Length of Diagonal strut.
αh=h*[( Em*t*sin2θ)/(4Ef *Ic *h)](1/4).
θ=Angle between horizontal and column
Ic=Moment of Inertia of adjoining column.
IV. RESULT AND DISCUSSION.
Nonlinear time history analysis, which explores more accurate responses of structure, is performed for all the models by direct integration technique, using the real ground motion data of earthquake. In this study after the analysis of 5 different time history data are evaluate for maximum story displacement , base shear and maximum bending moment and shear force in Beam are developing .
A. Story Displacement
For Maximum Storey Displacement EPS Core Reinforced Concrete Sandwich Panel (RCSP) based Structure has compare to Brick infill RCC Structure 57.46% less value shown for TH 1, 58.18% less value shown for TH 2, 54.62% less value shown for TH3.
B. Base Shear
For Maximum Base Shear EPS Core Reinforced Concrete Sandwich Panel (RCSP) based Structure has compare to Brick infill RCC Structure 32.42% more value shown for TH 1, 51.98% more value shown for TH 2, 34.43% more value shown for TH3.
This Analysis and design result of G+3 storied Displacement EPS Core Reinforced Concrete Sandwich Panel (RCSP) based and R.C.C with brick infill structure has been studied and represent here. The comparison result of these building model are as follows. 1) The displacement in EPS Core RCSP based Structure is merely less than RCC Structure, both are in permissible limit as prescribed by the codal provisons. 2) It was found that maximum Bending moment value in Beam of EPS Core RCSP based structure 50% to 70% more compare to R.C.C with brick infill structure. 3) It was found also that Maximum Shear Force value in in Beam of EPS Core RCSP based structure 70% to 80% more compare to R.C.C with brick infill structure. 4) In EPS Core RCSP based Structure load from four story load of slab through RCSP wall and load of RCSP wall is transferring to plinth beam witch is responsible for the generating more bending moment and shear force in plinth beam. Compare to RCC Structure where at each story load of slab and wall are transferring to column through the beam. 5) For EPS Core RCSP based structure has 30% to 52% more base shear shown compare to the R.C.C with brick infill structure.
[1] Adil Ahmad and Yogendra Singh “SEISMIC SAFETY EVALUATION OF AN EPS CORE SANDWICH WALL PANEL BUILDING”, International Conference on Composite Materials and Structures- ICCMS2017 Hyderabad, 27-29th December 2017 [2] Adil Ahmad, Yogendra Singh “Flexural behavior of Expanded Polystyrene core Reinforced Concrete Sandwich Panels with different construction methods and end conditions”, STRUCTURES(2021) [3] Ari Wibowo , Indradi Wijatmiko, and Christin R. Nainggolan “Cyclic Behaviour of Expanded Polystyrene (EPS) Sandwich Reinforced Concrete Walls”, Advances in Materials Science and Engineering Volume 2018. [4] Fabrizio Gara , Laura Ragni, Davide Roia, Luigino Dezi. “Experimental tests and numerical modelling of wall sandwich panels”, ENGINEERING STRUCTURE (2012) [5] Fabrizio Gara,Laura Ragni, Davide Roia, Luigino Dezi “Experimental behaviour and numerical analysis of floor sandwich panels”, ENGINEERING STRUCTURE (2012). [6] Mehmet Metin Kose “Parameters affecting the fundamental period of RC buildings with infill walls ” , ENGINEERING STRUCTURE (2009). [7] Sujan Pradhan,Yuebing Li,Yasushi Sanada “Seismic performance evaluation and risk assessment of typical reinforced concrete frame buildings with masonry infll and conventional vertical extension in Nepal”, 2021 [8] Avirup Sarkar , Adil Ahmad and Yogendra Singh “Seismic Design of Expanded Polystyrene Core Panel Based Building Systems”, International Conference on Earthquake Engineering and Post Disastor Reconstruction Planning 24 – 26 April, 2016, [9] Alessandra De Angelis , Maria Rosaria Pecce “Out-of-plane structural identification of a masonry infill wall inside beam column RC frames”, ENGINEERING STRUCTURE173 (2018) [10] Alessandra De Angelis, Marisa Pecce & Fernando Rossi “Linear time history analysis for the out-of plane seismic demand of infill walls in RC framed buildings”, Article in Bulletin of Earthquake Engineering · November 2015 [11] Mayur Thombare1 , Dr. Ajit Patil “Comparison of Structure Having Different Infill Material (Bricks, AAC Blocks and Hollow Concrete Blocks) Using E-Tabs”, International Journal of Innovative Research in Science, Engineering and Technology Volume 9, Issue 7, July 2020 | [12] A. Benayoune a, A. Aziz A. Samad b , D.N. Trikha c , A. Abdullah Abang Ali d , A.A. Ashrabov e “Structural behaviour of eccentrically loaded precast sandwich panels”, Construction and Building Materials 20 (2006) 713–724 Construction and Building MATERIALS [13] Ning Ninga,b,c, Zhongguo John Mac,d , Pengpeng Zhange , Dehu Yua,b , Jianlang Wanga “Influence of masonry infills on seismic response of RC frames under low frequency cyclic load”, ENGINEERING STRUCTURE183 (2019) [14] A. Sattainathan Sharma, R. Anjughap Priya, R. Thirugnanam and P. Rathna Priya “Comparative Study on Multi-storey Structure of R.C.C and Composite Material”, Indian Journal of Science and Technology, Vol 9(2), DOI: 10.17485/ijst/2016/v9i2/86363, January 201 [15] Marco Bovo , Michele Tondi, and Marco Savoia “Infill Modelling Influence on Dynamic Identification and Model Updating of Reinforced Concrete Framed Buildings”, Advances in Civil Engineering Volume 202 [16] S. Pujol a, D. Fick b “The test of a full-scale three-story RC structure with masonry infill walls”, Engineering Structures 32 (2010) 3112–3121