Power grid synchronization is a critical aspect of icing the stability and trust-ability of the electrical grid. The proper functioning of power grids relies on the synchronization of frequency and voltage across all connected factors. If a element gets a synchronization failure, it can affect in wide power outages, outfit damage, and other serious consequences. In this paper, we propose a system for detecting power grid synchronization failure grounded on the seeing of frequency and voltage beyond respectable range. The system utilizes a real- time monitoring system to continuously measure frequency and voltage across the grid, and it triggers an alarm when values fall outside of respectable ranges. We dissect the performance of the system using simulation results. On the bases of simulation result, apply it on tackle to provides a dependable and effective means for detecting power grid synchronization failure.
Introduction
I. INTRODUCTION
Power grids are complex systems that involve the transfer of electrical energy over long distances. To insure the stability and responsibility of these systems, the frequency and voltage of the electrical power must be accompanied across all factors of the grid. When the frequency and voltage of a element diverge from the values present in the rest of the grid, it can affect in a synchronization failure. These failures can beget wide power outages, outfit damage, and other serious consequences. As similar, it's critical to descry synchronization failures as snappily as possible so that they can be addressed and averted from raising. The detecting power grid synchronization failure system on seeing frequency or voltage beyond the respectable range is truly important in that power generation systems, where different force sources are connecting analogous together for supplying the uninterruptible power force to a single loaded machine bar. But for connecting the different force sources on a single machine bar there are some limitations, such the voltage and frequency both should be same of the connecting power sources.
II. METHODOLOGY
To descry power grid synchronization failures, we propose a system grounded on the seeing of frequency and voltage beyond respectable range. The system utilizes a real- time monitoring system to continuously measure frequency and voltage across the grid. When the measured values fall outside of respectable ranges, the monitoring system triggers an alarm. This allows for quick and effective discovery of synchronize
Transformer: In detecting power grid synchronization failure system on seeing frequence or voltage beyond the respectable range, the motor is used for step down the ac voltages. It steps down the 220V ac into 12V.
Bridge Rectifier:- In detecting power grid synchronization failure system on seeing frequency or voltage beyond the respectable range, the ground remedy is used for converting the ac voltages into dc voltages for supping the voltages to the other electronics factors
Block Diode:-In this system, the blocking diode is used for block the hamper opposition current for saving the motor.
Voltage Regulator: In detecting power grid synchronization failure system on seeing frequency or voltage beyond the respectable range, the voltage controller is used for regulating the dc voltages. also LM 7805 have been used for regulating the 12V dc into 5V dc.
LCD Display:- In detecting power grid synchronization failure system on seeing frequency
Voltage Detector: detecting power grid synchronization failure system on seeing frequency or voltage beyond the respectable range, the voltage sensor is used for detecting the voltage of voltage or voltage beyond the respectable range, the TV display is used for displaying the force frequency and voltages of different sources. It's connived with microcontroller and powered up with 5V dc. source.
Frequency Sensor: In detecting power grid synchronization failure system on seeing frequency or voltage beyond the respectable range, the frequency sensor is used for detecting the frequency of force source and functional amplifier is used for this purposes.
Microcontroller PIC 18F452: In detecting power grid synchronization failure system on seeing frequency or voltage beyond the respectable range, the microcontroller is used for the intelligent control of this system. It's powered up with 5V dc and is connived with TV display and voltage, frequency sensors.
Alternate Source: In this system, the 555- timekeeper integrated circuit IC is used as an alternate source. The frequency is changed by using this IC.
Relay: motorist In this system, the motorist IC is used for operating the weight relay and is connived with microcontroller..
Working of Circuit diagram
So basically the power will be of 3 phase from the actual power source now,the two parameters and analysis here first one is frequency and second one voltage so if the voltage is ranges between +-5 v then the relay activate due to sensing of low or high voltage and an abnormal condition arises so the tripping action is seen there ,as the rectangular led screen is provided so that the parameters are seen there like variation in frequency and voltage of all the three phases. (RYB respectively ) .two sensing relays are used here first one is ARMO-UFTR frequency relay and other one is SPAU 12 C relay is used against the protection for under and over voltage and to sense all the parameter accordingly the microcontroller is used so that microprocessor is used
V. RESULTS
Following observation are made:
Voltage (V)
LCD Display
LAMP
Indication
<240
Low Voltage
ON
240-250
Stable Voltage
OFF
>250
High Voltage
ON
Frequency (Hz)
LCD Display
LAMP
Indication
<48
Display frequency
ON
48-52
Display frequency
OFF
>52
Display frequency
ON
We estimated the system under a variety of conditions, including both normal and failure scripts. The results showed that the system is able of snappily and directly detecting synchronization failures. In addition, the results showed that the system is robust and dependable, indeed in the presence of noise and other disturbances.
Conclusion
In conclusion, the proposed method for detecting power grid synchronization failure based on the sensing of frequency and voltage beyond acceptable range provides a reliable and effective means for ensuring the stability and reliability of power grids. The results of our simulation study demonstrate the performance and robustness of the method, and they provide evidence that it is a valuable tool for preventing power outages and other serious consequences. With further refinement, this method has the potential to play a virtual role in the ongoing efforts to modernize and improve power grid systems.
References
[1] Shubhdeep Joshi,Tushar Parihar,Varun Kumar Shakya,”Detection of power grid synchronization failure on sensing frequency and voltage beyond acceptable range”-International journal of advance research in electrical Engineering,Vol.6.
[2] Karan Gupta, Shreyas Gupta, Kummad Varma, Anil Singh, Abhimanou Shrmma,”Detection power grid synchronization failure on sendsing bad voltage or frequency documentation”-International journal of Engineering research and general science,Vol.4.issue 2.
[3] Rohan Solanki,Divyesh Patel, Yuvraj Gharia,Daivik Sailor,BHumit Patel,Ashih Chaudhari,”Detection and protection of power grid synchronization failure ”-International research Journal of Engineering and technology,Vol 3,Issue 5.
[4] ].Nitin Dhama, Abhishek Gupta, Ajay Mundra, EktaRai, Shreya Singh, “Developing Islanding Arrangement Automatically For Grid on Sensing Voltage or Frequency Beyond Range”-International Journal of Engineering Research & Management Technology, Volume 2, Issue-2, March- 2015
[5] CH H S RAVI TEJA, “Analysis of Grid Synchronisation Techniques for Distributed Generation system During Grid Abnormalities-June 2013.